Pump unit technology | U. | HM | HE | HI nominal fixed speed |
HI nominal fixed power |
|
Lift rated load | kg | 330 | ||||
Single travel' s lenght | m | 8 | ||||
Cylinder rod diameter | mm | 90 | ||||
Pump unit oil tank volume | l | 110 | ||||
Pump unit oil delivery | l/min | 125 | ||||
Pump unit motor power | kW | 5.9 | 5.9 | 5.9 | 4.7 | |
Pump unit plate Cos φ | 0.8 | 0.8 | 0.98 | 0.98 | ||
Starting current | A | 90 | 89 | 17 | 14 | |
Pump unit oil cooler optional | Not installed | |||||
Consecutive up&down travels | N° | <110 | <140 | <180 | >200 | |
Rated current
|
Empty | A | 17 | 17.3 | 17 | 14 |
Full | A | 23 | 22 | 23 | 18 | |
Uptravel speed |
Empty | m/s | 0.6 | 0.63 | 0.63 | 0.63 |
Full | m/s | 0.6 | 0.62 | 0.62 | 0.5* | |
Downtravel speed |
Empty | m/s | 0.63 | 0.63 | 0.63 | 0.63 |
Full | m/s | 0.63 | 0.63 | 0.63 | 0.63 | |
Noise |
Up | dB | 58 | 65 | 58 | 58 |
Down | dB | 58 | 67 | 56 | 56 | |
Travel energy (100 travels) | kWh | 6 | 5.4 | 4.2 | 4.2 |
Martin Tang,
Key account manager for KONE
Lucifer Li,
Key account manager for Schindler
Jeff Bian,
Key account manager for OTIS